There's something satisfying about polar aligning a telescope mount the traditional way. Look through the polar scope, find Polaris, and adjust the mount until the star sits in the correct position on the illuminated reticle. No laptop to connect, no camera software to start, and no need to take your eyes away from the actual night sky.
The iOptron AccuAlign Polar Scope Kit (G2833) brings that familiar method of polar alignment to the GEM28 equatorial mount. It replaces the mount's electronic iPolar camera with a conventional optical polar scope featuring a dark-field illuminated reticle.
iPolar is a convenient electronic alignment system, particularly for astrophotographers who already have a computer beside their telescope. But not everyone wants to use a laptop just to get an equatorial mount pointed at the celestial pole. For those observers, the AccuAlign provides a practical alternative.
The kit includes the optical polar scope, its 12V LED illuminator and cable, and a protective cover. It installs in the GEM28's right ascension axis in place of the iPolar camera.
Dark-Field Illumination Makes Alignment Easier
One difficulty with an illuminated polar scope is that too much light can make the stars you're trying to see more difficult to find. If the entire field glows brightly, a faint reference star can become hard to distinguish against the illuminated background.
The AccuAlign uses dark-field illumination instead. The background remains dark while the reticle markings are illuminated, making it easier to see both the reference star and the position where it needs to be placed.
The reticle contains a clock-style scale divided into 12 hours, with smaller marks at ten-minute intervals. Concentric circles provide the appropriate reference distances for polar alignment.
In the Northern Hemisphere, the reticle uses Polaris, which is close to the north celestial pole but not located exactly on it. The correct position changes with the date and time, so simply placing Polaris in the center of the reticle doesn't provide the most accurate alignment.
Instead, the observer determines where Polaris should appear on the reticle, then adjusts the mount's altitude and azimuth controls until the star occupies that location.
Conveniently, iOptron's Go2Nova hand controller can provide the necessary Polaris position information. You can find it under the Alignment menu by selecting the position of Polaris. A compatible polar-alignment app or chart can also be used.
The reticle also includes markings for using Sigma Octantis in the Southern Hemisphere, although that star is considerably fainter than Polaris and more difficult to identify.
Replacing iPolar with AccuAlign
The AccuAlign is designed to install in the GEM28's right ascension axis, occupying the position normally used by the iPolar electronic camera.
Installation requires a set of metric Allen wrenches and careful attention to iOptron's instructions.
For a GEM28 equipped with iPolar, the general procedure is to remove the red rear cover of the right ascension axis, loosen the two retaining set screws, and carefully withdraw the iPolar camera.
With the mount placed in its Zero Position, the AccuAlign optical scope can then be inserted. One of the reticle's major marks should be oriented toward the 12 o'clock position before the retaining screws are secured.
Be careful not to overtighten those screws. The polar scope contains delicate optical components, including a glass reticle, and excessive pressure can cause damage.
The included LED illuminator threads into the polar scope. Its supplied cable connects the illuminator to the GEM28's DC 12V OUT connection. Once the mount is powered, the reticle illumination can be checked.
After installation, the optical scope should also be checked for alignment with the mount's right ascension axis. iOptron describes a procedure using a distant stationary object and the polar scope's reticle adjustment screws. This calibration is important because the reticle needs to remain centered on the polar axis as the mount rotates.
One limitation deserves special attention. With the optical polar scope installed, the GEM28's right ascension locking wrench cannot be inserted in its normal position because the polar scope extends into that space. Follow the manufacturer's instructions for handling the mount in this configuration, and always support the equipment when disengaging the gear switches.
The conversion is reversible. If you later decide to return to electronic polar alignment, the iPolar camera can be reinstalled using the appropriate procedure. Keep the original camera and its hardware in a safe place.
Powered by the Mount
The AccuAlign's LED illuminator draws its power from the GEM28 itself, so there is no separate illuminator battery to remember or replace.
The supplied cable connects to the mount's 12V accessory power output. When the mount is powered, the reticle can be illuminated for use.
The LED brightness is not electronically adjustable. If the reticle appears too bright, iOptron suggests partially blocking the illuminator to reduce the light reaching the reticle.
It's a simple arrangement, and one less battery-powered accessory to keep track of during an observing session.
Under the Night Sky
Once you've used an optical polar scope a few times, the alignment procedure becomes familiar. Set up the mount, look through the right ascension axis, identify Polaris, and turn the mount's altitude and azimuth adjustment knobs until the star reaches the correct reticle position.
From northern observing locations, Polaris stands relatively high above the horizon. That means looking through the polar scope can require bending down and looking upward at an uncomfortable angle. A low observing stool can make the job considerably easier.
One benefit of the GEM28 design is that the polar scope's view isn't blocked by the declination shaft in the way it is on some traditional German equatorial mounts. That allows the observer to check polar alignment without having to reposition the telescope simply to clear the optical path.
For visual observing, a carefully completed optical polar alignment is generally sufficient for keeping objects in the eyepiece during normal tracking.
For demanding long-exposure astrophotography, you may still wish to refine alignment with compatible software or a drift-alignment procedure. The AccuAlign provides a useful mechanical starting point, but its final accuracy depends on proper calibration and how carefully the alignment is performed.
Observing Tip: Check the Reticle Before Your First Night
Before depending on a newly installed polar scope, spend a few minutes checking its alignment in daylight.
Point the scope toward a distant stationary object, such as the corner of a building or the top of a distant antenna. Center that object in the reticle, then carefully rotate the mount's right ascension axis.
If the reticle is correctly aligned with the polar axis, the reference object should remain centered as the mount rotates.
If it moves away from the center, the reticle may need adjustment. iOptron's installation instructions describe how to make small corrections using the three reticle adjustment screws.
These adjustments should be made carefully, loosening and tightening the screws only slightly at a time. Do not overtighten them, as the reticle is glass.
Once calibrated, the polar scope is ready for nighttime use. Keep its protective cover installed when the scope isn't being used, and allow any accumulated dew to dry before storing the mount.
Know Before You Buy
-
Designed for the GEM28. This G2833 kit is specifically intended for the iOptron GEM28. The CEM26 uses a different kit, part number C2633.
-
Replaces iPolar. The optical polar scope and iPolar camera occupy the same mounting position. They cannot be used simultaneously.
-
No computer required for optical alignment. The Go2Nova hand controller can provide Polaris position information. A compatible app or chart is another option.
-
Requires initial alignment. Check that the polar scope's reticle is centered on the mount's right ascension axis after installation.
-
RA locking wrench cannot be used. The installed optical scope obstructs the locking-wrench opening. Follow iOptron's mounting and handling precautions.
-
Fixed LED brightness. The reticle illuminator doesn't have an electronic brightness adjustment.
-
Mount not included. This is the optical polar scope conversion kit only.
What's Included
- 1x iOptron AccuAlign optical polar scope (#3330)
- 1x 12V polar scope LED illuminator and connection cable (#3334)
- 1x Protective polar scope cover
GEM28 mount and installation tools are not included.
FAQ
- Will this work with my iOptron GEM28?
- Yes. The G2833 kit is designed for the GEM28 and installs in the right ascension axis in place of the iPolar electronic camera.
- Do I have to permanently remove iPolar?
- No. The conversion is reversible. You can reinstall the original iPolar camera later by following iOptron's replacement procedure. The two systems cannot occupy the mount at the same time.
- Do I need a laptop or smartphone to polar align?
- No. The optical scope works without a computer, and the Go2Nova hand controller can display the proper position for Polaris on the reticle. Compatible apps and charts are optional alternatives.
- Does the illuminator require batteries?
- No separate batteries are necessary. The included LED illuminator receives 12V power from the GEM28 mount through the supplied cable.
- Can I adjust the reticle brightness?
- The illuminator has no electronic brightness control. iOptron recommends partially covering the LED if less illumination is desired.
- Will it fit a CEM26?
- The G2833 kit is specifically listed for the GEM28. iOptron offers the C2633 AccuAlign kit for the CEM26.
- Is the polar scope calibrated when I install it?
- The reticle's alignment with the mount's right ascension axis should be checked after installation. iOptron provides instructions for adjusting the reticle using a distant stationary object.
Final Thoughts
Electronic polar alignment has made setting up an equatorial mount easier than ever, but there's still a place for a good optical polar scope.
The iOptron AccuAlign kit gives GEM28 owners the option of aligning their mount by eye, without connecting a laptop or running additional software. Its dark-field illuminated reticle makes the alignment markings easy to see against the night sky, while the included LED takes its power directly from the mount.
The installation requires some care, particularly when securing and calibrating the scope, and the original right ascension locking wrench can no longer be used. Those are worth understanding before making the change.
But for someone who prefers the familiar process of finding Polaris and making a few careful mechanical adjustments, the AccuAlign is a straightforward way to bring traditional optical polar alignment to the GEM28.